Incubator, Air-jacket (Advanced, IB4-AV)

Brand: JeioTech

Model:  IB4-03AV, 05AV, 10AV, 15AV

Origin: Korea

Availability: In Stock

Description

Features

Intuitive Large Touch Controller

  • Intuitive interface with 5-inch display.
  • Events and alerts in a single view with real-time graph.
  • Three frequent temperatures automatically suggested.
  • ‘Wait on / Wait off’ timer function.
  • Large intuitive display

  • Graphs for real-time process monitoring

Unique Structural Functions

  • Using Water tray delays media drying, making incubation time longer. (option)
  • Double stackable with stacking set (option) maximizes space utilization.
  • Water tray that minimizes media drying (option)

  • Increased space utilization by double stacking. (stacking set : option)
    * Double stacking example: (top) forced convection oven (bottom) forced convection incubator

Supervise Equipment with Real-time Monitoring

  • Monitor the temperature on BMS (Building Management System) for quick responses to abnormalities. (option)
  • Monitor and control anywhere, anytime with LC GreenBox. (Mobile Monitoring System, option)
  • Timely responses via BMS-connected monitoring (BMS port: option)

  • Real-time monitoring via mobile devices (LC GreenBox: option)

Convenient Experiment and Data Checking

  • Support RS-232/USB port and software making easy operation and data management from PC.
  • Test data are automatically stored and easily exported via USB; easy to edit data. (in CSV format)
  • Logs 36 recent events, including errors, opened door, etc.
  • Integrated with 21 CFR Part 11 compliant LC DataKeeper, suitable for GMP audits. (option)
  • Data storage using USB ports

  • Store recent 36 events

Reliable Temperature Control Performance

  • Temperature accuracy for wide range by 3-point calibration.
  • Ramp Control™, function that controls the rate of temperature rise by setting ramping rate(℃/min) per experiment.
  • Uniform temperature distribution through airflow optimized for uniform heat transfer. (within ±3.5 ℃ at 37℃)
  • Accurate temperature control with 3-point calibration

  • Ramp Control™ per experiment condition

Specification

Model IB4-03AV IB4-05AV IB4-10AV IB4-15AV
Chamber volume (L / cu ft) 25 / 0.88 60 / 2.19 114 / 4.03 150 / 5.30
Temperature Range (℃ / ℉) Amb. +5 to 80
/ Amb. +9 to 176
Fluctuation at 37℃ (±℃ / ℉) 0.10 / 0.18 0.10 / 0.18 0.15 / 0.27 0.10 / 0.18
Variation at 37℃ (±℃ / ℉) 0.31 / 0.56 0.48 / 0.86 0.46 / 0.83 0.55 / 0.99
Heating time to 37℃ (min.) 1) 44 40 46 49
Recovery time at 37℃ (min.) 5 9 9 9
Control panel 5 inch TFT Color LCD
Communication interface USB-B, RS-232
Function Recently event record 36 ea
Recommended temperature Suggest three frequently used temperature
Graph Available viewing stored and real-time graphs
Data storage Save your experiment data (in CSV format)
Temp. ramping rate (℃/min. | ℉/min) 0 to 2.0 | 0 to 3.6
Dimension
(W×D×H)
Interior (W x D x H, mm / inch) 300 x 210 x 400
/11.81 x 8.27 x 15.75
380 x 330 x 480
/14.96 x 12.99 x 18.9
485 x 350 x 655
/ 19.1 x 13.78 x 25.79
550 x 376 x 710
/ 21.62 x 14.8 x 27.95
Exterior (W x D x H, mm / inch) 478 x 527 x 604
/ 18.8 x 20.75 x 23.78
558 x 648 x 684
/ 21.97 x 25.5 x 26.93
663 x 677 x 859
/ 26.1 x 26.65 x 33.82
728 x 704 x 914
/ 28.66 x 27.7 x 36.0
Net weight (Kg / lbs) 31 / 68.34 40 / 88.18 55 / 121.25 60 / 132.28
Shelves Quantity of shelves (standard/max.) 2 / 4 2 / 5 2 / 8 2 / 9
Max. Load per shelf (Kg / lbs) 20 / 44.09 20 / 44.09 20 / 44.09 20 / 44.09
Electrical requirements (230V, 50 / 60Hz, A) 2.5 3.5 3.5 3.5
Cat. No.
AAH21755K AAH21765K AAH21775K AAH21785K
Electrical requirements (120V, 60Hz, A) 4.8 6.7 6.7 6.7
Cat. No.
AAH21753U AAH21763U AAH21773U AAH21783U

※ Technical data according to DIN 12880

 

Model IB4-03AV IB4-05AV IB4-10AV IB4-15AV
Chamber volume (L / cu ft) 25 / 0.88 60 / 2.19 114 / 4.03 150 / 5.30
Temperature Range (℃ / ℉) Amb. +5 to 80
/ Amb. +9 to 176
Fluctuation at 37℃ (±℃ / ℉) 0.10 / 0.18 0.10 / 0.18 0.15 / 0.27 0.10 / 0.18
Variation at 37℃ (±℃ / ℉) 0.31 / 0.56 0.48 / 0.86 0.46 / 0.83 0.55 / 0.99
Heating time to 37℃ (min.) 1) 44 40 46 49
Recovery time at 37℃ (min.) 5 9 9 9
Control panel 5 inch TFT Color LCD
Communication interface USB-B, RS-232
Function Recently event record 36 ea
Recommended temperature Suggest three frequently used temperature
Graph Available viewing stored and real-time graphs
Data storage Save your experiment data (in CSV format)
Temp. ramping rate (℃/min. | ℉/min) 0 to 2.0 | 0 to 3.6
Dimension
(W×D×H)
Interior (W x D x H, mm / inch) 300 x 210 x 400
/11.81 x 8.27 x 15.75
380 x 330 x 480
/14.96 x 12.99 x 18.9
485 x 350 x 655
/ 19.1 x 13.78 x 25.79
550 x 376 x 710
/ 21.62 x 14.8 x 27.95
Exterior (W x D x H, mm / inch) 478 x 527 x 604
/ 18.8 x 20.75 x 23.78
558 x 648 x 684
/ 21.97 x 25.5 x 26.93
663 x 677 x 859
/ 26.1 x 26.65 x 33.82
728 x 704 x 914
/ 28.66 x 27.7 x 36.0
Net weight (Kg / lbs) 31 / 68.34 40 / 88.18 55 / 121.25 60 / 132.28
Shelves Quantity of shelves (standard/max.) 2 / 4 2 / 5 2 / 8 2 / 9
Max. Load per shelf (Kg / lbs) 20 / 44.09 20 / 44.09 20 / 44.09 20 / 44.09
Electrical requirements (230V, 50 / 60Hz, A) 2.5 3.5 3.5 3.5
Cat. No.
AAH21755K AAH21765K AAH21775K AAH21785K
Electrical requirements (120V, 60Hz, A) 4.8 6.7 6.7 6.7
Cat. No.
AAH21753U AAH21763U AAH21773U AAH21783U

Accessories and Options

  • Wire shelf (2 shelves included in the basic product)

    Stainless Steel.
    Uniform temperature distribution based on high air permeability.
  • Perforated shelf

    Stainless Steel.
    Robust structure is ideal for heavy load samples.
  • Stacking Set

    Double stackable.
    Firm stacking allows efficient utilization of space.
    (※ When double stacking, the minimum control temperature of the upper chamber may be limited due to the heat generated by the lower chamber)
  • LC DataKeeper

    High-integrity software compliant with FDA 21 CFR Part 11.
    Integrated with JEIOTECH equipment to undergo GMP audits.
  • BMS Port

    Real-time equipment monitoring from a central monitoring facility.
    Useful for safety management at laboratories that operate multiple devices.
  • LC GreenBox (Mobile Monitoring System)

    Real-time monitoring and control via mobile app.
    Can connect up to four devices to a single LC GreenBox.
    Communication port connectivity via a RS-232 port.
  • Communication Port

    Allows PC-connection control and data extraction via dedicated software.
    Standard for IB4-V model, optional for IB4-S model.
  • Water Tray

    Stainless Steel.
    Minimizes media drying and extends incubation time for liquid media.
Shelves and Bracket IB4-03 IB4-05 IB4-10 IB4-15
Wire shelf FDA9739 FDA9738 FDA9737 FDA9736
Perforated shelf AAA125341 AAA125342 AAA125343 AAA125344
Stacking set AAA125547 AAA125549
BMS Port AAA125534
Communication Port AAA125533
Water Tray AAA125443 AAA125444 AAA125445 AAA125445
LC GreenBox AAHQ1011K
LC DataKeeper Basic SSA11001
LC DataKeeper Pro SSA11002
Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “Incubator, Air-jacket (Advanced, IB4-AV)”

Your email address will not be published. Required fields are marked *

Shipping & Delivery

MAECENAS IACULIS

Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.

ADIPISCING CONVALLIS BULUM

  • Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
  • Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
  • Diam parturient dictumst parturient scelerisque nibh lectus.

Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.