Incubator (General / Economy)

Brand: Jeio Tech

Model:  IB4-03AS, 05AS, 10AS, 15AS

Origin: Korea

Availability: In Stock

An air-jacket type of incubator, standard type

Description

Features

Intuitive Touch Controller

  • Intuitive interface with 3.5-inch display.
  • ‘Wait on / Wait off’ timer function.
  • 3.5-inch touch display

  • Wait on & Wait off timer

Reliable Temperature Control Performance

  • Temperature accuracy for wide range by 3-point calibration.
  • The upper and lower temperature limits can be set, enabling alerts for deviations to trigger quick actions.
  • Uniform temperature distribution through airflow optimized for uniform heat transfer. (within ±0.55 ℃ at 37℃)
  • Accurate temperature control with 3-point calibration

  • Settings for temperature deviation

Convenient Experiment and Data Checking

  • Support RS-232/USB port and software making easy operation and data management from PC. (option)
  • Monitor and control anywhere, anytime with LC GreenBox. (Mobile Monitoring System, option)
  • Monitor the temperature on BMS (Building Management System) for quick responses to abnormalities. (option)
  • Integrated with 21 CFR Part 11 compliant LC DataKeeper, suitable for GMP audits. (option)
  • Manipulation via PC (option)

  • Real-time monitoring via mobile devices (LC GreenBox: option)

Enhanced Safety and Convenience

  • Implemented with the highest-level overheating prevention system. (Patent 10-0397583)
  • Over Temperature Limiter.
  • Complaint to IEC Class II protection standards and temperature protection in line with DIN 12880 Class 3.1.
  • Logs the last 12 events, including run times, stops, and errors.
  • Double stackable with stacking set (option) maximizes space utilization.
  • Logs the recent 12 events

  • Increased space utilization by double stacking (stacking set : option)
    * Double stacking example: (top) forced convection oven / (bottom) forced convection incubator

Multiple Features to Minimize Incubation Failure

  • Using Water tray delays media drying, making incubation time longer. (option)
  • Automatically resume the control of previous operations when restored within 30 seconds from blackouts.
  • Controller can be locked with the button on the top, preventing any actions from unintended pressing.
  • Abnormalities are notified with audiovisual alerts to trigger quick actions.
  • Water tray that minimizes media drying (option)

  • Audiovisual alerts to notify abnormalities

Specification

Model IB4-03AS IB4-05AS IB4-10AS IB4-15AS
Chamber volume (L / cu ft) 25 / 0.88 60 / 2.19 114 / 4.03 150 / 5.30
Temperature Range (℃ / ℉) Amb. +5 to 80 / Amb. +9 to 176
Fluctuation at 37℃ (±℃ / ℉) 0.10 / 0.18 0.10 / 0.18 0.15 / 0.27 0.10 / 0.18
Variation at 37℃ (±℃ / ℉) 0.31 / 0.56 0.48 / 0.86 0.46 / 0.83 0.55 / 0.99
Heating time to 37℃ (min.) 1) 44 40 46 49
Recovery time at 37℃ (min.) 5 9 9 9
Control panel 3.5 inch TFT Color LCD
Communication interface USB-B, RS-232 (option)
Function Recently event record 12 ea
Dimension
(W×D×H)
Interior (W x D x H, mm / inch) 300 x 210 x 400
/11.81 x 8.27 x 15.75
380 x 330 x 480
/14.96 x 12.99 x 18.9
485 x 350 x 655
/ 19.1 x 13.78 x 25.79
550 x 376 x 710
/ 21.62 x 14.8 x 27.95
Exterior (W x D x H, mm / inch) 478 x 527 x 604
/ 18.8 x 20.75 x 23.78
558 x 648 x 684
/ 21.97 x 25.5 x 26.93
663 x 677 x 859
/ 26.1 x 26.65 x 33.82
728 x 704 x 914
/ 28.66 x 27.7 x 36.0
Net weight (Kg / lbs) 32 / 68.34 40 / 88.18 55 / 121.25 60 / 132.28
Shelves Quantity of shelves (standard/max.) 2 / 4 2 / 5 2 / 8 2 / 9
Max. Load per shelf (Kg / lbs) 20 / 44.09 20 / 44.09 20 / 44.09 20 / 44.09
Electrical requirements (230V, 50 / 60Hz, A) 2.5 3.5 3.5 3.5
Cat. No.
AAH21555K AAH21565K AAH21575K AAH21585K
Electrical requirements (120V, 60Hz, A) 4.8 6.7 6.7 6.7
Cat. No.
AAH21553U AAH21563U AAH21573U AAH21583U

 

Accessories and Options

  • Wire shelf (2 shelves included in the basic product)

    Stainless Steel.
    Uniform temperature distribution based on high air permeability.
  • Perforated shelf

    Stainless Steel.
    Robust structure is ideal for heavy load samples.
  • Stacking Set

    Double stackable.
    Firm stacking allows efficient utilization of space.
    (※ When double stacking, the minimum control temperature of the upper chamber may be limited due to the heat generated by the lower chamber)
  • LC DataKeeper

    High-integrity software compliant with FDA 21 CFR Part 11.
    Integrated with JEIOTECH equipment to undergo GMP audits.
  • BMS Port

    Real-time equipment monitoring from a central monitoring facility.
    Useful for safety management at laboratories that operate multiple devices.
  • LC GreenBox (Mobile Monitoring System)

    Real-time monitoring and control via mobile app.
    Can connect up to four devices to a single LC GreenBox.
    Communication port connectivity via a RS-232 port.
  • Communication Port

    Allows PC-connection control and data extraction via dedicated software.
    Standard for IB4-V model, optional for IB4-S model.
  • Water Tray

    Stainless Steel.
    Minimizes media drying and extends incubation time for liquid media.
Shelves and Bracket IB4-03 IB4-05 IB4-10 IB4-15
Wire shelf FDA9739 FDA9738 FDA9737 FDA9736
Perforated shelf AAA125341 AAA125342 AAA125343 AAA125344
Stacking set AAA125547 AAA125549
BMS Port AAA125534
Communication Port AAA125533
Water Tray AAA125443 AAA125444 AAA125445 AAA125445
LC GreenBox AAHQ1011K
LC DataKeeper Basic SSA11001
LC DataKeeper Pro SSA11002
Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “Incubator (General / Economy)”

Your email address will not be published. Required fields are marked *

Shipping & Delivery

MAECENAS IACULIS

Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.

ADIPISCING CONVALLIS BULUM

  • Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
  • Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
  • Diam parturient dictumst parturient scelerisque nibh lectus.

Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.