Features
Control range
- Temperature range from -5 to 85°C Humidity range from 20 to 85% RH

Performance
- Microprocessor PID control / Temperature calibration / Automatic tuning.
- Rapid humidity control is achieved by adapting the humidification tank interior to the chamber.
- Air-tight door closure with perfect sealed packing.
– Heat-resistant silicone packing completely blocks high heat leakage from the inner chamber.
Convenience
- Two different sized models available to suit any users’ needs.
- Corrosion resistant stainless steel chamber.
- Cable port for introduction of external probes or wires.
– 50mm diameter cable port comes standard on the left side of the unit.
– Additional 50mm or 80mm diameter cable ports, custom ordered. (optional) - Inner glass door with entry ports for handling samples without affecting inner chamber temperature and humidity. (optional)
- Casters for easy mobility during installation or relocation.
- User friendly LCD controller.
– Colorful interactive touch type LCD controller.
– Set point temperature and present temperature are clearly shown together on display.
– Sufficient programmable control support.
– Operating progress can be shown in graph mode for better data understanding.
– Automatic start/stop can be programmed for unattended operations.
– Display indicates abnormal temperature changes or power failures.
– Selective bilingual language support.
(Korean / English or English / Chinese, selectable only when placing an order)
– Temperature and other operating parameters can be recorded using a six channel digital recorder.(optional) - Computer interface.
– RS-485 communication port (optional) enables connection up to maximum 32 units. Simultaneous monitoring and operating of multiple units is an available feature.
– Program patterns are simple to set with the use of our software.
– Easy to check status of real-time operations. Graph data supports easy understanding.
– Storage and documentation of programs.
– Data with saving capabilities in excel and text format.
– Storage of program information, backup of value settings, recovery, and temperature values.
– RS-232 communication port as standard offer.
| Description | No |
|---|---|
| Programmable pattern capacity | 100 |
| Pattern repeat time | 999 |
| Part repeat time | 255 |
| Max. segments per a pattern | 100 |
| Available max. segments* | 2000 |
| Programmable process time per a segment | 0 to 99 hr. 59 min. |
* It is possible to set 100 segments per pattern, but the maximum number of segments is not 10,000 (100 pattern x 100 segment) but 2,000.
Stability test ICH guideline Q1A (R2)
- Operating progress visible through graph mode for better data analyzation.
- Cyclic defrost system, designed to work excellently for the long period stability test operation. (※Temperature and humidity changes may occur during automatic defrost.)
- Maintenance of water supply are easily performed with a front water tank.
– Water level check indicated by water level bar in the tank. - Water supply during operation is also available for long term test purposes.
- Direct water system provides user great convenience when performing long-term test. (optional)
Photostability test ICH guidelineQ1B (Option 2)
- Built in UV and fluorescent lamps for uniformed luminescence.
- Equipped with movable UV and VIS sensors .
- Independent lamp controller
– An indicator for Total usage time of UV and fluorescent lamps. - Convenient set function of cumulative dosage and lamp Of
Safety
- Built in door lock with a key.
- Automatic shut off after overheat alarm.
- Low and empty water level alarm.
- Power supply leakage breaker.
- Over current protection.
- Open door alarm.
-

Lamp controller
-

LCD controller
-

Digital recorder (optional)
-

Water level indicator
Specification
| Model | TH-ICH-300 | TH-ICH-800 | ||
|---|---|---|---|---|
| Chamber volume (L / cu ft) | 300 / 10.6 | 760 / 26.8 | ||
| Controller | PID control (LCD Type) | |||
| Temperature 1) | Range | without humidity (℃ / ℉) | -5 to 85 / 23 to 185 without Light 0 to 85 / 32 to 185 with Light |
|
| with humidity (℃ / ℉) | +15 to 85 / 59 to 185 with Light | |||
| Fluctuation 1) (±℃ / ℉) at 40℃ / 60%RH | 0.3 / 0.55 | 0.3 / 0.55 | ||
| Variation 1) (±℃ / ℉) at 40℃ / 60%RH | 0.5 / 0.9 | 0.7 / 1.3 | ||
| Time | Heating | 25min (20℃ → 85℃) | 30min (20℃ → 85℃) | |
| Cooling | 35min (20℃ → -5℃) | 40min (20℃ → -5℃) | ||
| Humidity | Range (%RH) | 20 to 85 ※ See page 231 for more detailed humidity range check. |
||
| Fluctuation 2) (±%RH) at 60%RH / 40℃ | 3 | |||
| Variation 2) (±%RH) at 60%RH / 40℃ | 5 | |||
| Light source (ICH Q1B option 2) | Cool white 3) | 6,000 lux | 6,500 lux | |
| Ultraviolet-A 3) | 4.5 W/㎡ | 5 W/㎡ | ||
| Light uniformity | VIS. : ±10%UVA : ±15% | VIS. : ±15%UVA : ±15% | ||
| Typical time required to reach ICH Recommendation of 1.2 million lux-hr |
≒ 200Hr | ≒ 184Hr | ||
| Typical time required to reach ICH recommendation of 200 W-hr/m2 |
≒ 50Hr | ≒ 40Hr | ||
| Refrigeration | System | Air – cooled | ||
| Refrigerant | R- 404A | |||
| Water tank | Capacity (L / cu ft) | 15 / 0.53 | ||
| Water quality | pH6.2 ~ 7.2, Electrical conductivity 20㎲ / cm to below | |||
| No. of wire shelves (standard / max.) | 2 / 8 | 2 / 17 | ||
| Distance of between shelves (mm / inch) | 60 / 2.4 | 60 / 2.4 | ||
| Max. load per shelf (kg / lbs) | 25 / 55.1 | 40 / 88.2 | ||
| Permitted total load (kg / lbs) | 75 / 165.3 | 100 / 220.5 | ||
| Dimension (W×D×H) | Interior (mm / inch) | 750×650×650 / 29.5×25.6×25.6 | 750×880×1160 / 29.5×34.6×45.7 | |
| Exterior (mm / inch) | 1130×985×1520 / 44.5×38.8×59.8 | 1220×1215×1965 / 48×47.8×77.4 | ||
| Net weight (kg / lbs) | 280±10 / 617±22 | 400±10 / 882±22 | ||
| Cable port | Basically one hole provided / Ø 50mm (2”), Optionally max. two holes available / Ø 50 or 80mm (2 or 3.2”) |
|||
| Interface port | Basically RS-232C, [RS-485 : optional] | |||
| Electrical requirements | AC230V, 1ph, 60Hz | 14.7 A | 23.5 A | |
| Cat.No. | AAHC1005K | AAHC1015K | ||
| AC230V, 1ph, 50Hz | 14.7 A | 23.5 A | ||
| Cat.No. | AAHC1005K | AAHC1015K | ||
Accessories and Options
for Floor Standing Chambers
Accessory check list□ Standard ○ Optional
| Description | Models | |||||
|---|---|---|---|---|---|---|
| TH-G | TH-I | TH-KH | TH-TG | TH-ICH | TH-CR | |
| Recorder (6 points) | ○ | ○ | ○ | ○ | ○ | ○ |
| Recorder (digital, 6 channels) | ○ | ○ | ○ | ○ | ○ | ○ |
| interface converter RS-485C → 232C included a cable (5m / 16.4ft) | ○ | ○ | ○ | ○ | ○ | ○ |
| Interface cable (5m / 16.4ft) | ○ | ○ | ○ | ○ | ○ | ○ |
| Warning signal lamp | ○ | ○ | ○ | ○ | ○ | ○ |
| Inner glass door | ○ | ○ | ○ | ○ | ○ | – |
| Viewing window | □ | □ | □ | □ | – | □ |
| Wire shelf | □ | □ | □ | □ | □ | □ |
| Perforated shelf | ○ | ○ | ○ | ○ | ○ | ○ |
| Cable port (Ø 50mm / 2”) | □ | □ | □ | □ | □ | □ |
| Cable port (Ø 80mm / 3.2”) | ○ | ○ | ○ | ○ | ○ | ○ |
| Temperature sensor (RTD type) | □ | □ | □ | □ | □ | □ |
| Humidity sensor | □ | □ | □ | □ | □ | □ |
| Fluorescent lamp (Cool White) | – | – | – | – | □ | – |
| UVA lamp | – | – | – | – | □ | – |
| UV sensor | – | – | – | – | □ | – |
| Illumination Sensor | – | – | – | – | □ | – |
| HEPA filter | – | – | – | – | – | □ |
| ULPA filter | – | – | – | – | – | ○ |
| Water cartridge tank (Water Container) | □ | □ | □ | □ | – | □ |
| Water purifier | ○ | ○ | ○ | ○ | ○ | ○ |
| Direct water system | ○ | ○ | ○ | ○ | ○ | ○ |
1) 80mm cable access hole is NOT available for 25L chamber.
Ordering information
| Cat. No. | Description | Suitable for |
|---|---|---|
| AAA8T500 | Recorder (6 points) | All models |
| AAA8T505 | Recorder (digital, 6 channels) | All models |
| AAA8T540 | interface converter RS-485C → 232C included a cable (5m / 16.4ft) |
All models |
| AAA8T542 | Interface cable (5m / 16.4ft) | All models |
| AAA80550 | Warning signal lamp | All models |
| AAA81552 | Inner glass door | TH-G/I/KH-180 |
| AAA81551 | TH-G/I/KH-300, 408, CR-270 | |
| AAA81550 | TH-G-800, 1000 | |
| AAAC2501 | TH-TG-180 | |
| AAAC2502 | TH-TG-300, 408 | |
| AAAC2503 | TH-TG-800, 1000 | |
| AAA81554 | TH-ICH-300 | |
| AAA81555 | TH-ICH-800 | |
| AAA8T610 | Cable port (Ø 50mm / 2”) | All models |
| AAA8T611 | Cable port (Ø 80mm / 3.2”) | All models |
| 00CFA0001185 | Temperature sensor (RTD type) | All models |
| 00CFA0007113 | Humidity sensor | All models |
| 00RTD0001190 | Fluorescent lamp (cool white) | TH-ICH-300 |
| 00RTD0001191 | TH-ICH-800 | |
| 00RTD0001188 | UVA lamp | TH-ICH-300 |
| 00RTD0001189 | TH-ICH-800 | |
| AAA80680 | THE-680 UV sensor | TH-ICH-300/800 |
| AAA80681 | THE-681 Illumination sensor | TH-ICH-300/800 |
| AAA80661 | Door lock device | TH-ICH-300/800 |
| 00EDA0009184 | HEPA filter | TH-CR-270 |
| 00EDA0009175 | ULPA filter | TH-CR-270 |
| AAA80622 | Water cartridge tank | All models |
| Cat. No. | Description | Suitable for |
|---|---|---|
| AAA8T625 | Water purifier | All models |
| AAA80620 | Direct water system | All models |
| 00EDA0008212 | Wire shelf | TH-G/I/KH-180 |
| 00EDA0008213 | TH-G/I/KH-300 | |
| 00EDA0008214 | TH-G/I/KH-408 | |
| 00EDA0008215 | TH-G-800 | |
| 00EDA0008216 | TH-G-1000 | |
| 00RTD0001302 | TH-TG-180 | |
| 00RTD0001303 | TH-TG-300 | |
| 00RTD0001300 | TH-TG-408 | |
| 00RTD0001304 | TH-TG-800 | |
| 00RTD0001301 | TH-TG-1000 | |
| 00RTD0001305 | TH-G/TG-1500 | |
| 00RTD0001196 | TH-ICH-300 | |
| 00RTD0001198 | TH-ICH-800 | |
| 00STT0001040 | TH-CR-270 | |
| AAA80602-1 | Perforated shelf | TH-G/I/KH-180 |
| AAA80602-2 | TH-G/I/KH-300 | |
| AAA80602-3 | TH-G/I/KH-408 | |
| AAA80602-4 | TH-G-800 | |
| AAA80602-5 | TH-G-1000 | |
| AAA80604-11 | TH-TG-180 | |
| AAA80604-12 | TH-TG-300 | |
| AAA80604-13 | TH-TG-408 | |
| AAA80604-14 | TH-TG-800 | |
| AAA80604-15 | TH-TG-1000 | |
| AAA80604-16 | TH-G/TG-1500 | |
| AAA80604-2 | TH-ICH-300 | |
| AAA80604-4 | TH-ICH-800 | |
| AAA80603-1 | TH-CR-270 |
MAECENAS IACULIS
Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.
ADIPISCING CONVALLIS BULUM
- Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
- Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
- Diam parturient dictumst parturient scelerisque nibh lectus.
Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.

Reviews
There are no reviews yet.